November 15, 2006 at 10:04 am
I am not cluster guy so would like to know how i can resolve the issue that i have.
Cluster iActive/Passive & is on RAID 5. one of the drive fails, so we put new drive & after that NODE 1 is able to see that new drive but NODE 2 is not & due to this problem NODE 2 is not starting. i didn't get enough information about error message. so i am planning to do some thing from scratch or to fix the issue in a more better way. or if some one can give me links or steps that when Drive fails then you need to do certain things before you remove the drive & put NEW one in. Any steps to do so will be appreciated & thanking in advance.
November 16, 2006 at 5:03 am
shared drives have to be added to the server resource groups which have the various nodes allocated etc.
check in cluster admin manager
[font="Comic Sans MS"]The GrumpyOldDBA[/font]
www.grumpyolddba.co.uk
http://sqlblogcasts.com/blogs/grumpyolddba/
November 16, 2006 at 9:49 am
hmmm ... it does not add up .... one drive failing on RAID 5 still leaves the array, which shows as one logical unit, usable. Is this a shared RAID array on attached storage or on a SAN ? If it is on a SAN absolutely nothing should have happened. If it is on attached storage, well it depends on the vendor's hardware and software.
RegardsRudy KomacsarSenior Database Administrator"Ave Caesar! - Morituri te salutamus."
Viewing 3 posts - 1 through 3 (of 3 total)