Linked Server Returns Communication Link Failure after Unspecified Error

  • Morning all,

    Over the weekend, one of my servers decided that the linked server was no longer going to function.

    I have had this error once in a while of the occasional semaphore timeout period has expired - due to some type of internet lag.

    But not this time.

    I can not get the object to work at all any more.

    I tested the Linked Server object, and the Test connection - passes, yet when I try to use it in any simple query - it dies.

    I am getting 3 messages -- 1 OLE DB provider "SQLNCLI11" returned message "Unspecified Error" and 2 "Communication link failure".

    Then it says Msg 121 Level 16, State 1 Line 0

    TCP Provider: The semaphore timeout period has expired.

    Anyone have any pointers to which direction I should go with this?

    My first thoughts are maybe the server needs to be rebooted.

    Any pointers are appreciated.

    Thanks,

    Tonya

  • Looks similar to what we had encounter with our servers when DTC was not enabled on a link server. Maybe this will help you with resolving the error:

    http://stackoverflow.com/questions/7473508/unable-to-begin-a-distributed-transaction

  • Found the Answer !!

    Apprently there were some networking routing changes done, and a Delay in the Router was added.

    The Delay was removed, and now everything works fine.

    Thanks for taking the time to review!

    Tonya

Viewing 3 posts - 1 through 3 (of 3 total)